Features:
  • NOT RECOMMENDED FOR NEW DESIGNS. For new designs, use the EBR series.
  • Active power factor correction (PF) > 0.9 (PF ≥ 0.8 for 230 Vac models below 10 W) and THD < 20%
  • Compatible with industry standard TRIAC (forward-phase or leading-edge) / ELV (reverse-phase or trailing-edge) phase-cut dimmers
  • Protections: output open load, over-current and short-circuit (hiccup), and over-temperature with auto recovery
  • Conducted and radiated EMI: FCC CFR Title 47 Part 15 Class B at 120 Vac and EN55015 (CISPR 15) at 220/230/240 Vac
  • Complies with ENERGY STAR® luminaire specification and DLC (DesignLight Consortium®) technical requirements
  • IP20-rated case with silicone-based potting
  • 94V-0 flammability rating
  • 90°C maximum case hot spot temperature
  • Lifetime: 50,000 hours min at 70°C case temperature
  • Class 2 power supply

Applications:
  • Architectural
  • Commercial lighting
  • Downlight
Application Notes:
> 1 Page Datasheet
Email Me the Full Datasheet:
Input Voltage Max Output Power Output Voltage Output Current Range Efficiency THD Max Case Temp Power Factor Dimming Method Dimming Range Start Time
120 or 230 Vac nominal 18 W 12 to 42 Vdc 200 mA to 1 A Constant Current up to 84% < 20% 90º C (measured at the hot spot) >0.9 Forward-Phase, Reverse-Phase 10-100% (% of Iout) 1 s max
Loading Products
ERP Part Number Nominal
Input Voltage (VAC)
Output Current (mA) Power (W) Voltage Range (Vdc) Case Type Dimming Status Availability
ELR018U-0700-24 120 700 8.4 14 - 24 IP20 Round Plastic For/Rev Phase, 10-100% production Check >
ELR018E-1000-18 120 1000 18.0 12 - 18 IP20 Round Plastic For/Rev Phase, 10-100% production Check >
ELR009U-0200-42 120 200 8.4 28 - 42 IP20 Round Plastic For/Rev Phase, 10-100% production Check >
Notes:
  • For additional options of output current and output voltage, contact your sales representative or send an email to: SaveEnergy@erp-power.com