Constant Current LED Drivers

ESSV Series

6 TO 40 W, TRI-MODE DIMMING™ (0-10 V & TRIAC/ELV)
Input Voltage Max Output Power Output Voltage Output Current Range Efficiency THD       Max Case Temp Power Factor Dimming Method Dimming Range Start Time
120 to 277 Vac 40 W 20 to 42 Vdc 250 mA to 1.4 A Constant Current Up to 87% < 20% 90º C (measured at the hot spot) > 0.9 Forward-Phase, Reverse-Phase & 0-10 V 1-100% (% of Iout) 400 ms
Features:
  • Same features as the ESS/ESST series but with a thermally-enhanced plastic case, 5VA flammability and UL Class P
  • Compatible with TRIAC (forward-phase or leading-edge), ELV (reverse-phase or trailing-edge) and 0-10 V dimmers
  • UL Class P
  • 90°C maximum case hot spot temperature
  • Class 2 power supply
  • Lifetime: 50,000 hours at 70°C case hot spot temperature
  • IP66-rated case with silicone-based potting
  • Protections: output open load, over-current and short-circuit (hiccup), and over-temperature with auto recovery
  • Conducted and radiated EMI: Compliant with FCC CFR Title 47 Part 15 Class B (120 Vac) and Class A (277 Vac)
  • Complies with ENERGY STAR®, DLC (DesignLight Consortium®) and CA Title 24 technical requirements
  • Worldwide safety approvals

Applications:
  • Architectural
  • Commercial lighting
  • Downlight
  • Indoor lighting
  • Office
  • Outdoor LED Light
  • Residential light
FC CertifiedUL CertifiedCA Title 245 Year Warrenty
Technical Documentation:
> Datasheet
Email me the additional documentation:
Loading Products
ERP Part Number Nominal
Input Voltage (Vac)
Output Current (mA) Power (W) Voltage Range (Vdc) Case Type Dimming Status Availability
ESSV030W-0700-42 120 to 277 700 29.4 24 - 42 IP66 Rectangular Plastic For/Rev Phase & 0-10V, 1-100% production Check >
ESSV030W-0500-42 120 to 277 500 21.0 24 - 42 IP66 Rectangular Plastic For/Rev Phase & 0-10V, 1-100% production Check >
ESSV015W-0300-42 120 to 277 300 12.6 24 - 42 IP66 Rectangular Plastic For/Rev Phase & 0-10V, 1-100% production Check >
Notes:
  • For additional options of output current and output voltage, contact your sales representative or send an email to: SaveEnergy@ERP-Power.com